Skip to content

EasyAccess 2.0 on PC

EasyAccess 2.0 is provided as a standalone program that can be installed on the PC. It can be used independent of the EasyBuilder software suite.

Download the software from Weintek’s website at:
https://www.weintek.com/globalw/Software/EasyAccess.aspx

Step-by-step for establishing EasyAccess 2.0 connection.

1. Launch EasyAccess 2.0.exe.
2. Enter Domain name, Domain user’s username and password, and then click [Login].
3. Once logged in, the program will list user’s HMIs and their statuses.
4. Click on connect button to establish connection to an online HMI. Once connected, the virtual IP address will be displayed. It is now possible to connect directly to the HMI by net services such as VNC, HMI Viewer, or FTP.
5. When finished, click on disconnect button to terminate the connection.

VNC Viewer
For models supporting VNC server, one may use VNC viewer to access the HMI. Please install a VNC Viewer of your choice, and provide its executable file (.exe) location to EasyAccess 2.0 application in [Settings] » [Path]. After you have successfully made the connection, should clicking on the VNC icon yields no response, launch VNC viewer separately and use the virtual IP address obtained in EasyAccess 2.0 as the destination IP address.

Please install a VNC Viewer of your choice: TightVNCRealVNC

HMI Viewer
Non-cMT models support using HMI Viewer to access HMI. Provide a suitable gui_e30.exe location to EasyAccess 2.0 application in [Settings] » [Path]. gui_e30.exe is contained within EasyAccess 2.0 and EasyBuilder Pro installation folder, where the latter always contains the most up-to-date version.

cMT Viewer
cMT models support using cMT Viewer to access HMI. cMT Viewer is contained within EasyAccess 2.0 and EasyBuilder Pro installation folder, where the latter always contains the most up-to-date version.

Installing adapters

During the first program run, the software will detect whether necessary adapters are present. If not, they will be installed automatically.

Log in

Domain name, Domain username and password are required for login.


Login to EasyAccess 2.0

If a user enables Multi-Factor Authentication (MFA), a time-based one-time password (six digits) must be entered to log in. For more details, see Multi-Facetor Authentication (MFA)

Main screen

Once successfully logged in, the main screen will show all HMIs for the user and their online statuses. HMIs that are online will have a connect button and a setting button. There is no limit on the number of HMIs that can be simultaneously connected from the program. However, once an HMI is connected by a user, it goes into “occupied” state and cannot be connected by another user before the existing connection has been terminated.


EasyAccess 2.0 Main Screen

Functions of icons on Main screen:

IconFunction
Domain Traffic Usage(Top-up Card)
HMI search filter
Tile view/ List view
Event Logs
Settings
Logout of current user

Displays connection logs.

Settings

TabDescription
General » 
Network traffic
Options:
- Show all HMI Network traffic
- Disable Weintek P2P
- Enable sending log for debug
InformationSoftware version and the terms of usage
LanguageSelect the language
Languages available: Languages available: English, French, Italian, Spanish, Russian, Simplified Chinese, Traditional Chinese, Korean, German, Japanese, Polish, Dutch
AccountClick the link to access the Weincloud web management account or delete the currently logged-in account. After providing a reason for the account deletion, the system will send an email to the user's email address. If the account to be deleted is an admin account, it can only be deleted if there are no HMIs bound under that domain. Deleting the admin account will also result in the deletion of the domain.
Path » Executable

Select executable (*.exe) path for VNC viewer, HMI Viewer, and cMT Viewer, used to launch the viewers when connections are established.

Use built-in VNC Viewer
If enabled, the built-in VNC Viewer will be used as the interface when connecting to the HMI via VNC.

VNC executable path
Location of the .exe executable of the VNC viewer. VNC viewer must be installed separately.

HMI Viewer path
Location of the GUI (gui_e30.exe), for use with iE/XE/eMT/mTV series.

Note: Login, logout, add/setting/delete accounts related operations might cause problem on HMI Viewer. Recommand using VNC viewer for these operations.

cMT Viewer path
Location of the cMT Viewer, for use with cMT/MT X series.

EBPro folder
Location of the EasyBuilder Pro folder, where libraries necessary for PCHMI transfer are located.

Note: Please try to keep GUI updated as it is the necessary executable for running the HMI Viewer. A copy of GUI and cMT Viewer which was most current as of the date of EasyAccess 2.0 release is included in the installation. An update of GUI may be required when programming environment of the HMI was updated; in this case, find it in the latest version of EasyBuilder Pro.

HMI States and Access Setting

HMI can be in one of the states: Offline, Online, Connected, and Occupied.

OfflineOnline
ConnectedOccupied

The usage or meaning of each icon:

IconFunction
HMI name. If the name is displayed in blue font, it indicates a nickname.
Virtual IP address. Click to copy the IP address to clipboard.
Set up pass-through IP address
Connect to the HMI
Disconnect from the HMI
Access the HMI with VNC viewer (installed separately). 

Access the HMI with HMI Viewer

Note: Login, logout, add/setting/delete accounts related operations might cause problem on HMI Viewer. Recommand using VNC viewer for these operations.

Events
When push notification is enabled, the notification of triggered events will be shown here.

Access Setting
Enter access setting of the HMI, which allows using VNC Viewer or HMI Viewer.
To use VNC Viewer, set executable path in Settings page.
To use HMI Viewer, set executable path in Settings page. Also, set how project upload and history should be handled.


HMI Viewer setting (only when enabled)

FTP URL with password shortcut

You may enter FTP password beforehand and copy the FTP URL when you long press, right click on the VPN IP, or click the copy button next to 'Password in FTP URL'

 

Notification setting

Enable push notification. When an event is triggered on HMI, EasyAccess 2.0 can send push notification about the event.
The language used by push notification can be selected in [Language & Font], and Label Tag Library in EasyBuilder Pro can be used to configure multiple languages.

Connection Log

Clicking on the LOG icon brings out the detail connection logs with the VPN, Authentication, and UAC server. The GUI tab shows information relevant to the use of HMI Viewer. In additional to viewing them here, it is also possible to save the logs as a file.


Connection Logs

Usage Display

The HMI’s total data usage to date for the current month will be displayed.


Usage Display

Trouble shooting

If connection error happens, click the "Exclamation mark" icon to check the error details

Error Happens

Error Details

You can also use Diagnosis to help check those connection problems